Ductless Mini-Split System Installation

Strona 2 - Tools Required

STEP 7 Install supplied wall sleeve.

Strona 3 - Find a suitable location

STEP 8 Prepare Indoor Unit refrigerant piping connections.

Strona 4 - (Condenser)

STEP 9 Remove the seal caps from the indoor refrigerant lines. *Note: Nitrogen charge may be released & a hissing sound may be heard when the firs

Strona 5

STEP 10 Guide the line set through the 2 ½ inch hole.

Strona 6 - STEP 3

*Note: Refrigerant Pipes

Strona 7

STEP 11 Remove the seal caps from the refrigerant lines.

Strona 8

STEP 12 Tighten connections using wrenches working in opposite direction. *Note: For best result use Torque Wrench.

Strona 9 - STEP 6

STEP 13 Connect the supplied drain line extension.

Strona 10

STEP 14 A. Arrange the pipes, cables & drain hose. B. Lag the pipe joints with insulating material, securing it with supplied UV vinyl tape. C. R

Strona 11 - STEP 8

*Note: Always keep drain line at the bottom of bundle.

Strona 12 - & a hissing

Tools Required • Philips Screw Driver • Level • Drill • 2 ½ inch Hole Saw • Allen Wrench 5.5 & 6 • Vacuum Pump • 410 A Gauge • Torque Wrench

Strona 13 - inch hole

STEP 15 Reconnect Indoor Unit to Mounting Plate.

Strona 14 - *Note: Refrigerant Pipes

STEP 16 Install vibration pads and secure Outdoor Unit.

Strona 15 - STEP 11

*Note: Optional L Bracket System The bracket must be secured to the structure of the building using the proper industry standard anchors for heavy lo

Strona 16 - STEP 12

STEP 17 – Outdoor Unit (Condenser) Connection Remove valve cover.

Strona 17 - STEP 13

STEP 18 Remove seal cap protector.

Strona 18 - STEP 14

*Note: Pipe Connection

Strona 19

STEP 19 Connect refrigerant lines to outdoor unit valves.

Strona 20 - STEP 15

STEP 20 Bleed/ Purge system using a Vacuum Pump.

Strona 21 - STEP 16

*Note: Vacuum Bleeding

Strona 22

*Note: Vacuum line for 10 to 15 minutes, or to 30 microns.

Strona 23 - (Condenser) Connection

STEP 1 - Indoor Unit (Evaporator) Find a suitable location. • Install the indoor unit on a level & structurally sound wall that is not subject to

Strona 24 - STEP 18

STEP 21 - Electrical Connection Remove condenser electrical cover.

Strona 25 - *Note: Pipe Connection

STEP 22 Plug Quick-Connect terminal from Indoor Unit into the Quick-Connect terminal from the Outdoor Unit.

Strona 26 - STEP 19

STEP 23 Connect ground to metal plate.

Strona 27 - STEP 20

STEP 24 Connect line from service box to compressor.

Strona 28 - *Note: Vacuum Bleeding

STEP 25 Re-install the electrical cover.

Strona 29

STEP 26 – Purge Excess Air Open high side valve ¼ turn counter clockwise.

Strona 30

STEP 27 Remove service valve cap.

Strona 31 - STEP 22

STEP 28 Press schrader (Service) valve for 3 seconds.

Strona 32 - STEP 23

STEP 29 Open liquid valve completely counter clockwise. *Note: Valve must be fully open.

Strona 33 - STEP 24

STEP 30 Open suction valve completely counter clockwise. *Note: Valve must be fully open.

Strona 34 - STEP 25

STEP 2 - Outdoor Unit (Condenser) Find the perfect location for the condenser unit.

Strona 35 - STEP 26 – Purge Excess Air

STEP 31 Check for leaks at all joint connections.

Strona 36 - STEP 27

STEP 32 Wrap remaining refrigerant line with UV insulation tape.

Strona 37 - STEP 28

FINAL STEP Test the system. A. Turn the breaker on. B. Using the remote control, turn the Indoor Unit on. C. Check all system functions for

Strona 38 - STEP 29

Maximum Height & Distances

Strona 39 - STEP 30

STEP 3 Remove Mounting Plate from Indoor Unit.

Strona 40 - STEP 31

STEP 4 Find secure location for the Mounting Plate and mark the holes. *Note: Be sure that the plate is level.

Strona 41 - STEP 32

STEP 5 Attach Mounting Plate to structure.

Strona 42 - Test the system

STEP 6 Drill a 2 ½ inch Hole *Note: The hole must be drilled on an angle of about 30 degrees; the exterior opening should be at least ¼ inch lower th